Detail výsledku

Mathematical model of mechanical testing of bone-implant (4.5 mm LCP) construct

URBANOVÁ, L.; BLAŽEK-FIALOVÁ, I.; SRNEC, R.; PĚNČÍK, J.; KRŠEK, P.; NEČAS, A. Mathematical model of mechanical testing of bone-implant (4.5 mm LCP) construct. ACTA VETERINARIA BRNO, 2012, vol. 81, no. 2, p. 211-215. ISSN: 0001-7213.
Typ
článek v časopise
Jazyk
angličtina
Autoři
Urbanová Lucie, MVDr.
Blažek-Fialová Iva, MVDr.
Srnec Robert, MVDr
Pěnčík Jan, prof. Ing., Ph.D., CIS ‒ Kancelář ředitele (CIS), FAST (FAST), PST (FAST)
Kršek Přemysl, doc. Ing., Ph.D., UTKO (FEKT)
Nečas Alois, prof. MVDr., Ph.D., MBA
Abstrakt

The study deals with the possibility of substituting time- and material-demanding mechanical testing of a bone defect fixation by mathematical modelling. Based on the mechanical model, a mathematical model of bone-implant construct stabilizing experimental segmental femoral bone defect (segmental ostectomy) in a miniature pig ex vivo model using 4.5 mm titanium LCP was created. It was subsequently computer-loaded by forces acting parallel to the long axis of the construct. By the effect of the acting forces the displacement vector sum of individual construct points occurred. The greatest displacement was noted in the end segments of the bone in close proximity to ostectomy and in the area of the empty central plate hole (without screw) at the level of the segmental bone defect. By studying the equivalent von Mises stress SIGMAeqv on LCP as part of the tested construct we found that the greatest changes of stress occur in the place of the empty central plate hole. The distribution of this strain was relatively symmetrical along both sides of the hole. The exceeding of the yield stress value and irreversible plastic deformations in this segment of LCP occurred at the acting of the force of 360 N. These findings are in line with the character of damage of the same construct loaded during its mechanic testing. We succeeded in creating a mathematical model of the bone-implant construct which may be further used for computer modelling of real loading of similar constructs chosen for fixation of bone defects in both experimental and clinical practice.

Klíčová slova

Fracture fixation, implant failure, material deformation, yield stress, displacement vector sum.

URL
Rok
2012
Strany
211–215
Časopis
ACTA VETERINARIA BRNO, roč. 81, č. 2, ISSN 0001-7213
Vydavatel
University of Veterinary and Pharmaceutical Sciences in Brno
Místo
Brno, Czech Republic
DOI
BibTeX
@article{BUT93877,
  author="Lucie {Urbanová} and Iva {Blažek-Fialová} and Robert {Srnec} and Jan {Pěnčík} and Přemysl {Kršek} and Alois {Nečas}",
  title="Mathematical model of mechanical testing of bone-implant (4.5 mm LCP) construct",
  journal="ACTA VETERINARIA BRNO",
  year="2012",
  volume="81",
  number="2",
  pages="211--215",
  doi="10.2754/avb201281020211",
  issn="0001-7213",
  url="https://actavet.vfu.cz/81/2/0211/"
}
Soubory
Pracoviště
Ústav počítačové grafiky a multimédií (UPGM)
Ústav pozemního stavitelství (PST)
Nahoru